Metric sensor M12x1

  • AC and DC sensors available
  • High switching frequencies up to 4000 kHz
  • Fully encapsulated versions to protection class IP67
  • Sturdy metal enclosure
  • M8, M12 connector or cable versions
  • Temperature range from -25°C up to +70°C
  • Short circuit-proof versions
  • Sensing distances from 2 mm to 8 mm
  • Cable / connector versions
  • 10 – 36 V DC or 76-250 V AC
  • PNP / NPN versions
  • NO / NC versions
  • Function indicators
Art. No. Type STEP IGES Assembly instructions Spec sheet
6532103001M12 - shortened - NPN - NC - flush - Sn 2 mm - Cable 2 m
6532103002M12 - Standard - NPN - NC - flush - Sn 2 mm - Cable 2 m
6532104001M12 - shortened - NPN - NC - non-flush - Sn 4 mm - Cable 2 m
6532104002M12 - Standard - NPN - NC - non-flush - Sn 4 mm - Cable 2 m
6532143001M12 - shortened - NPN - NC - flush - Sn 2 mm - Plug M12
6532143002M12 - Standard - NPN - NC - flush - Sn 2 mm - Plug M12
6532144001M12 - shortened - NPN - NC - non-flush - Sn 4 mm - Plug M12
6532144002M12 - Standard - NPN - NC - non-flush - Sn 4 mm - Plug M12
6532303001M12 - shortened - NPN - NO - flush - Sn 2 mm - Cable 2 m
6532303002M12 - Standard - NPN - NO - flush - Sn 2 mm - Cable 2 m
6532304001M12 - shortened - NPN - NO - non-flush- Sn 4 mm - Cable 2 m
6532304002M12 - Standard - NPN - NO - non-flush - Sn 4 mm - Cable 2 m
6532343001M12 - shortened - NPN - NO - flush - Sn 2 mm - Plug M12
6532343002M12 - Standard - NPN - NO - flush - Sn 2 mm - Plug M12
6532344001M12 - shortened - NPN - NO - non-flush - Sn 4 mm - Plug M12
6532344002M12 - Standard - NPN - NO - non-flush - Sn 4 mm - Plug M12
6532703001M12 - shortened - PNP - NC - flush - Sn 2 mm - Cable 2 m - IO-Link
6532703002M12 - Standard - PNP - NC - flush - Sn 2 mm - Cable 2 m - IO-Link
6532704001M12 - shortened - PNP - NC - non-flush - Sn 4 mm - Cable 2 m - IO-Link
6532704002M12 - Standard - PNP - NC - non-flush - Sn 4 mm - Cable 2 m - IO-Link
6532743001M12 - shortened - PNP - NC - flush - Sn 2 mm - Plug M12 - IO-Link
6532743002M12 - Standard - PNP - NC - flush - Sn 2 mm - Plug M12 - IO-Link
6532744001M12 - shortened - PNP - NC - non-flush - Sn 4 mm - Plug M12 - IO-Link
6532744002M12 - Standard - PNP - NC - non-flush - Sn 4 mm - Plug M12 - IO-Link
6532903001M12 - shortened - PNP - NO - flush - Sn 2 mm - Cable 2 m - IO-Link
6532903002M12 - Standard - PNP - NO - flush - Sn 2 mm - Cable 2 m - IO-Link
6532904001M12 - shortened - PNP - NO - non-flush - Sn 4 mm - Cable 2 m - IO-Link
6532904002M12 - Standard - PNP - NO - non-flush - Sn 4 mm - Cable 2 m - IO-Link
6532943001M12 - shortened - PNP - NO - flush - Sn 2 mm - Plug M12 - IO-Link
6532943002M12 - Standard - PNP - NO - flush - Sn 2 mm - Plug M12 - IO-Link
6532944001M12 - shortened - PNP - NO - non-flush - Sn 4 mm - Plug M12 - IO-Link
6532944002M12 - Standard - PNP - NO - non-flush - Sn 4 mm - Plug M12 - IO-Link
Top